Inverter Heat Pumps R32

suitable for cold climates

R32 small unit new
Badges

Warranty - 3 years

Heat pump CGK-030V3L-B​

Power: 12 kW
Power supply: 380-420 V

Important: Apart from the heat pump, high efficiency (low electricity bills) is only achieved with professional installation. We have been dealing with heating, cooling and ventilation for more than 25 years and guarantee that we will complete your project using the best installation practices.

Price: 3113,00 € (6088,50 лв.) VAT included

Category
Buy withtbi bank logo
13 x €254.96 (13 x 498.66 лв.)

Functionalities

icon-display
5-inch color touchscreen

The 5-inch color touchscreen allows you to easily control the temperature and set the system modes. With a modern and clear interface, it can quickly check error codes, ensuring you can change or program your room temperature at any time.

icon-energy-class
ERP A+++ energy class

Highly energy efficient as the CAREL series controller, the new R32 full inverter heat pumps can also achieve ERP A+++ energy level. They have a maximum heating capacity of 9.5KW to 22KW, with a max COP of 5.89.

icon-software-update
Possibility of software update remotely and with just one click

If a software update is needed, the system will inform you so that you can upgrade the controller software with one click anytime, anywhere as long as you are connected to the internet. The update may only take a few minutes depending on the speed of your internet connection.

icon-r32
R32 Refrigerant

R32 refrigerant is more environmentally friendly than other traditional refrigerants. Its ability to allow the inverter heat pump to recharge and recycle more efficiently than some other refrigerants means that the unit can operate at much higher efficiency.

icon-defrosting
Intelligent defrosting

Niko Therm independently developed its own PID intelligent defrost control mode. When the defrost conditions are met, the defrost mode will be automatically entered to prevent the unit from being confused with defrosting and energy consumption, which will improve the reliability and economy of the entire unit.

icon-max-temperature-65
Max. outlet water temperature reaches 65°C

By combining R32 refrigerant and inverter heating technology, the heat pump can operate from -30°C to 45°C, maintaining high COP and stability. More importantly, the max. leaving water temperature reaches 65℃ without electric heating.

Key components

R32 key components 1024x661 en ver

Technical characteristics

Model CGK-030V3L-B
Power supply/Refrigerant V/Hz/Ph 380-420/50/3 - R32
Max. heating power (A7℃/W35℃) kW 11.6
COP (A7℃/W 35℃) W /W 4.42
Heating power Min./Max.(A7℃/W35℃) kW 5.34 / 11.60
Heating consumption Min./Max.(A7℃/W35℃) W 966 / 2624
COP Min./Max.(A7℃/W 35℃) W /W 4.42 / 5.53
Max. Heating power(A7℃/W45℃) kW 11.1
COP (A7℃/W 45℃) W /W 3.54
Heating power Min./Max.(A7℃/W45℃) kW 5.12 / 11.14
Heating consumption Min./Max.(A7℃/W45℃) W 1220 / 3149
COP Min./Max.(A7℃/W 45℃) W /W 3.54 / 4.20
Max. cooling capacity(A35℃/W18℃) kW 10.6
EER (A35℃/W 18℃) W /W 3.43
Cooling capacity Min./Max.(A35℃/W18℃) kW 4.87 / 10.58
Cooling consumption Min./Max.(A35℃/W18℃) W 1183 / 3084
EER Min./Max.(A35℃/W 18℃) W /W 3.43 / 4.12
Max. cooling capacity (A35℃/W7℃) kW 7.5
EER(A35℃/W 7℃) W /W 2.4
Cooling capacity Min./Max.(A35℃/W7℃) kW 3.43 / 7.46
Cooling consumption Min./Max.(A35℃/W7℃) W 948 / 3108
EER Min./Max.(A35℃/W 7℃) W /W 2.40 / 3.62
Maximum power consumption kW 3.94
Maximum current A 8.31
Cross-section of power wires mm² 5x2.5
Fuse A 13A
Compressor type - number Twin Rotary - 1
Fan Number of fans 1
Air flow rate m3/h 3000
Power W 100
Water heat exchanger Type Plate-shaped
Pressure drop kPa 20
Pipe connections Inch G1"
Water flow rate Min./Rated./Max. L/S 0.35 0.55 0.92
Noise level dB(A) 59
Dimensions (L×W×H) mm 1110*475*810
Package size(L×D×H) (Carton) mm 1165*490*960
Package size (L×D×H) (Plywood) mm 1220*540*970
Self-weight kg 88
Weight with packaging (Carton) kg 105
Weight with packaging (Plywood) kg 116

Heating capacity at different outdoor temperatures

Outside air temperature ℃ Heating power (KW)
-25 5.25 5.17 5.50
-24 5.56 5.54 5.71
-22 5.91 5.89 6.08
-20 6.03 6.01 6.20
-18 6.39 6.51 6.40
-16 6.80 6.93 6.80
-15 6.93 7.07 6.94
-7 8.46 8.95 8.25
-3 9.21 9.63 9.00
2 10.44 10.91 10.20
7 11.60 11.14 10.91
12 12.18 11.69 12.20
20 12.79 12.28 12.80
Water temperature (inlet/outlet) ℃ 30/35 40/45 50/55
Cgk030v3l b

COP variation at different outdoor temperatures

Outside air temperature ℃ COP kW/kW
-25 1.98 1.79 1.40
-20 2.25 2.11 1.65
-15 2.62 2.29 1.79
-7 3.23 2.67 2.08
-3 3.50 2.90 2.26
2 3.85 3.25 2.54
7 4.42 3.54 2.76
12 4.95 3.82 2.98
20 5.54 4.47 3.49
Water temperature (inlet/outlet) ℃ 30/35 40/45 50/55
Cgk030v3l b cop en ver

Installation diagram

Installation scheme 1024x604 en ver
tbi bank loading
please wait
Scroll to Top