Air-to-water heat pumps (Monoblock) R290 DC Inverter

suitable for cold climate

NewProject

Heat pump NikoTherm CGK-101V4-B

Power: 30kW
Power supply: 380-420V

Price: 9610,00 € (18795,53 лв.) VAT included

Buy withtbi bank logo
13 x €787.08 (13 x 1539.39 лв.)

Features

icon-display
5 inch color touch screen

The 5-inch color touchscreen allows you to control the temperature and set the system's operating mode with ease. With a modern and clean interface, the screen easily checks for error codes, ensuring you can change or program the room temperature at any time.

icon-r290-qa16vitk688s8ddwyr8rvqukwqwv0hpwn0yfgg2cha
Refrigerant 290

The refrigerant R290 is more environmentally friendly than other traditional refrigerants. Its ability to provide the heat pump with more efficient recharge and recycling capabilities than other refrigerants means that the unit can operate at much higher efficiency.

icon-software-update
Remote software upgrade with one click

If a software update is required, the system will notify you so that you can update the controller software with one click at any time and from anywhere, provided that you are connected to the Internet. The update only takes a few minutes, depending on the speed of your Internet connection.

icon-defrosting
Intelligent defrosting

NIKO Therm has its own intelligent PID type defrost control mode. When defrost conditions are met, the defrost mode will automatically turn on to prevent the module from being confused during defrosting and consuming energy, which will improve the reliability and economy of the unit.

Key components

R290 highlights 3 new 2 en ver

Technical characteristics

Model CGK-101V4-B
Electrical power supply V/Hz/Ph 380-420/50/3
Maximum heating power (A7℃/W35℃) kW 30
COP (A7℃/W35℃) W/W 3.85
Heating power Min./Max.(A7℃/W35℃) kW 10.05 / 30.00
Consumption in Heating mode Min./Max.(A7℃/W35℃) W 2072 / 7792
COP Min./Max.(A7℃/W35℃) W/W 3.85 / 4.85
Maximum heating power (A7℃/W45℃) kW 28.1
COP (A7℃/W45℃) W/W 3.36
Heating power Min./Max.(A7℃/W45℃) kW 9.05 / 28.05
Consumption in Heating mode Min./Max.(A7℃/W45℃) W 2363 / 8348
COP Min./Max.(A7℃/W45℃) W/W 3.36 / 3.83
Maximum Cooling Capacity (A35℃/W18℃) kW 23.9
EER (A35℃/W18℃) W/W 3.28
Cooling capacity Min./Max.(A35℃/W18℃) kW 9.29 / 23.90
Consumption in Cooling mode Min./Max.(A35℃/W18℃) W 2497 / 7287
EER Min./Max.(A35℃/W18℃) W/W 3.28 / 3.72
Maximum Cooling Capacity(A35℃/W7℃) kW 19.2
EER(A35℃/W7℃) W/W 2.64
Cooling capacity Min./Max.(A35℃/W7℃) kW 8.20 / 19.20
Consumption in cooling mode Min./Max.(A35℃/W7℃) W 2391 / 7273
EER Min./Max.(A35℃/W7℃) W/W 2.64 / 3.43
Maximum electrical power kW 13.50
Maximum current A 20.50
Cross-section of power wires mm² 6.0
Circuit breaker A 32A
Compressor Brand HITACHI
Refrigerant/ Charged quantity Kg R290/2.1
Fan Type / DC
Quantity / 2
Debit m3/h 11000
Speed RPM 900
Power W 250
Water heat exchanger Type / Plate-shaped
Pressure drop kPa 40
Pipe connections Inch G1.2"
Noise level dB(A) 64
Moisture protection / IPX4
Dimensions (L×W×H) mm 1249*509*1558
Package size(L×D×H) mm 1340*575*1715
Weight kg 250
Energy class: (According to (EU)No 811/2013 Table 2) -- A+++
Energy class: (According to (EU)No 811/2013 Table 1) -- A++
Outdoor temperature range.(℃) -25℃~45℃
Water temperature - DHW.(℃) 10℃~70℃(DHW)
Water temperature - Heating.(℃) 10℃~70℃(Heating)
Water temperature - Cooling.(℃) 12℃~30℃(Cooling)
Note: (1) Heating conditions: entering/leaving water: 30℃/35℃, Outdoor temperature: DB 7℃/WB 6℃;
(2) Heating conditions: water inlet/outlet: 40℃/45℃, Outdoor temperature: DB 7℃/WB 6℃;
(3) Cooling conditions: entering/leaving water: 23℃/18℃, Outdoor temperature: DB35℃/WB24℃;
(4) Cooling conditions: entering/leaving water: 12℃/7℃, Outdoor temperature: DB35℃/WB24℃;

Additional information

  1. Additional electric heater. Activation of the additional electric heater function in the settings menu. In heating mode, the additional heater is switched on when all of the following conditions are met:
    • Activated function in the menu;
    • The outdoor temperature ≤ the set outdoor temperature for the function (Default setting 0℃);
    • Water temperature ≤ Set temperature – Deviation for electric heater (Setting 5℃);
    • More than 50 minutes have passed since the compressor started (Adjustable);
  2. The heater is switched off when at least one of the following conditions is met:
    • The outdoor temperature ≥ The set outdoor temperature for the function + 3℃;
    • Water temperature ≥ Set water temperature;
    • External temperature sensor damaged; (4) Machine shutdown.
  3. Defrost function. In heating mode, the outdoor heat exchanger works as an evaporator. If the outdoor temperature is too low, frost may form on the heat exchanger, which reduces the efficiency of the unit. In such a case, the operation mode must be temporarily changed to Cooling to melt the frost and restore the high efficiency of the unit. Defrost conditions: Defrosting will start if the following conditions occur simultaneously:
    • Time between two defrost cycles ≥ set time: 45min;
    • The outdoor temperature ≤ the defrost outdoor temperature set point, for a time of at least 2 seconds, the default value is 15℃ (This condition is ignored when the temperature sensor is faulty);
    • Outdoor temperature – evaporation temperature ≥ Set temperature difference, for a period of at least 2 minutes, Factory setting 5℃; (This condition is ignored if the sensor is damaged)
    • Evaporation temperature ≤ Defrost setpoint temperature, for a period of 2 seconds, Factory setting -1℃;
  4. Manual defrosting is also activated without the above conditions being met. Defrosting ends if one of the following conditions is met:
    • Defrost time ≥ maximum defrost time (Default setting 8min).
    • Heat exchanger temperature ≥ set temperature to exit defrost mode (default setting 15℃)
    • Turning off the machine

Heating capacity at different outdoor temperatures

Model CGK-101V4-B
Outdoor temperature Heating power (kW)
30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75
-25 12.69 12.64 12.58 12.03 11.63



-20 15.16 15.00 14.86 14.78 14.70 13.80


-15 17.29 16.93 16.68 16.59 16.52 16.14 14.95 13.83
-7 21.60 21.01 20.62 19.95 19.73 19.02 18.55 18.00 16.53
-2 23.47 22.86 22.18 21.63 21.07 20.21 19.68 19.23 18.55
2 26.08 25.23 24.64 24.03 23.41 22.69 21.86 21.15 20.61
7 30.01 29.22 28.05 27.12 25.87 24.93 24.03 23.16 22.46
12 31.08 30.20 29.05 28.11 26.84 26.12 25.28 24.33 21.96
20 28.82 26.95 24.50 23.68 21.12 20.68 20.48 20.02 19.63
CGK 101V4 B

Conversion coefficient under different temperature conditions

Model CGK-101V4-B
Outdoor temperature COP /kW
30/35 35/40 40/45 45/50 50/55 55/60 60/65 65/70 70/75
-25 1.93 1.82 1.66 1.45 1.28



-20 2.16 2.01 1.82 1.66 1.53 1.43


-15 2.40 2.30 2.00 1.97 1.70 1.52 1.42 1.30
-7 2.84 2.60 2.36 2.18 1.96 1.87 1.60 1.40 1.18
-2 3.05 2.87 2.69 2.43 2.18 2.05 1.81 1.52 1.26
2 3.32 3.05 2.73 2.55 2.25 2.19 1.97 1.73 1.55
7 3.86 3.54 3.36 2.85 2.46 2.35 2.23 1.90 1.68
12 4.49 4.28 3.58 3.18 2.85 2.62 2.42 2.21 2.01
20 5.35 4.86 4.08 3.78 2.96 2.76 2.55 2.35 2.08